{"product_id":"ad-4212d-weighing-module-canada","title":"A\u0026D AD-4212D Microgram Precision Weighing Modules","description":"\u003ch2\u003eA\u0026amp;D AD-4212D Microgram Precision Weighing Modules\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eA\u0026amp;D AD-4212D Series\u003c\/strong\u003e is a microgram precision weighing module platform designed for advanced laboratory automation, pharmaceutical production, chemical workflows, robotics, OEM equipment, formulation systems, and high-accuracy production weighing.\u003c\/p\u003e\n\u003cp\u003eWith readability down to \u003cstrong\u003e0.001 mg \/ 1 µg\u003c\/strong\u003e, internal sensitivity adjustment, RS-232C communication, underhook support, overload protection, and a compact weighing sensor design, the AD-4212D Series is built for demanding applications where standard precision weighing modules are not enough.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch3 style=\"margin-top: 0;\"\u003eBuilt for Microgram-Level Automation\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 0;\"\u003e\n\u003cli\u003ePharmaceutical and chemical automation\u003c\/li\u003e\n\u003cli\u003eMicro-dosing, analytical weighing, and fine formulation\u003c\/li\u003e\n\u003cli\u003eRobotic weighing and automated sample handling\u003c\/li\u003e\n\u003cli\u003eAdvanced laboratory automation and research systems\u003c\/li\u003e\n\u003cli\u003eOEM machinery, enclosed weighing cells, and high-precision production equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWhy Choose the A\u0026amp;D AD-4212D Series?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicrogram readability:\u003c\/strong\u003e Models are available with readability down to 0.001 mg \/ 1 µg for demanding high-precision workflows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal sensitivity adjustment:\u003c\/strong\u003e Built-in internal weight supports one-touch sensitivity adjustment without relying only on external calibration weights.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation-ready design:\u003c\/strong\u003e Integrated A-to-D converter supports direct connection to a PC or PLC through the appropriate communication setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-232C communication:\u003c\/strong\u003e Standard serial communication supports connection to compatible PCs, controllers, printers, displays, and automation systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload protection:\u003c\/strong\u003e Protection mechanism helps reduce risk from vertical and transverse overload caused by actuator movement or equipment malfunction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable response characteristics:\u003c\/strong\u003e Helps users balance weighing speed and stability in environments affected by drafts, vibration, or automation movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall breeze break included:\u003c\/strong\u003e Helps support stable microgram-level measurements in sensitive weighing environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnderhook support:\u003c\/strong\u003e Supports suspended weighing applications such as magnetic material weighing and density measurement setups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom pan or receptacle support:\u003c\/strong\u003e Allows users to design and attach a preferred weighing pan or fixture for the application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 cleaning protection:\u003c\/strong\u003e IP65 rating applies when the water-resistant cap is placed on the pan support boss after removing the weighing pan and pan support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCanadian A\u0026amp;D support:\u003c\/strong\u003e Supplied through A\u0026amp;D Weighing Wholesale Canada, operated by Cambridge Environmental Products, an authorized Canadian A\u0026amp;D master distributor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAvailable AD-4212D Models\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eReadability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eTypical Stabilization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eBest Fit\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAD-4212D-33\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e32 g\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0.001 mg \/ 1 µg\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 7 sec\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHighest-resolution D Series model for demanding microgram-level automation tasks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAD-4212D-32\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5.1 g \/ 32 g dual range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0.001 mg \/ 0.01 mg\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 7 sec\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSmart Range applications that need microgram precision at lower weights and higher capacity after range switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAD-4212D-32S\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5.1 g \/ 32 g dual range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0.001 mg \/ 0.01 mg\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eConfirm before ordering\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eCompact configuration applications where installation space is limited. Confirm availability and specifications before ordering.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAD-4212D-302\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e320 g\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0.01 mg\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 7 sec\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHigher-capacity analytical automation where 10 µg readability is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAD-4212D-301\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e320 g\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0.1 mg\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 3 sec\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eLargest D Series capacity with faster stabilization and 0.1 mg readability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #fff8e5;\"\u003e\n\u003ch3 style=\"margin-top: 0;\"\u003eModel Availability Note\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003eA\u0026amp;D’s official AD-4212D specification table lists AD-4212D-33, AD-4212D-32, AD-4212D-302, and AD-4212D-301. If you require the AD-4212D-32S compact configuration, contact us before ordering so we can confirm current availability, specifications, and lead time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAD-4212D Series Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMicrogram precision weighing module \/ analytical weighing sensor system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eA\u0026amp;D AD-4212D Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eOfficial Models Listed by A\u0026amp;D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAD-4212D-33, AD-4212D-32, AD-4212D-302, AD-4212D-301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCapacity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5.1 g \/ 32 g dual range up to 320 g, depending on model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eReadability Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0.001 mg \/ 1 µg to 0.1 mg, depending on model and range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eTypical Stabilization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 7 seconds for AD-4212D-33, AD-4212D-32, and AD-4212D-302; approx. 3 seconds for AD-4212D-301 when set to FAST under suitable conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eFrom 0.002 mg standard deviation depending on model and test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eLinearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eFrom ±0.02 mg depending on model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eSensitivity Drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e±2 ppm\/°C from 10°C to 30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eWeighing Pan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eØ34 mm or Ø50 mm depending on model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRS-232C serial interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCalibration \/ Sensitivity Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eInternal sensitivity adjustment weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eIP65 when the water-resistant cap is placed on the pan support boss after removing the weighing pan and pan support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCommon Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMicrogram weighing, pharmaceutical automation, chemical workflows, laboratory automation, robotics, micro-dosing, formulation, density measurement, and OEM weighing systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSmart Range Model Notes\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAD-4212D-32\u003c\/strong\u003e is a Smart Range model. It provides microgram readability in the precision range and automatically switches to the standard range when the weighing value exceeds the precision range capacity.\u003c\/p\u003e\n\u003cp\u003eThe display returns to the precision range after performing RE-ZERO \/ tare. This makes the Smart Range design useful for automated applications with tare loads, small containers, or fixtures where fine readability is still needed during part of the weighing process.\u003c\/p\u003e\n\u003ch2\u003eEngineering and Integration Notes\u003c\/h2\u003e\n\u003cp\u003eThe AD-4212D Series is intended for users who need microgram or analytical weighing performance inside a machine, enclosure, or automation system. It is different from a standard bench balance because the weighing sensor can be installed into custom fixtures, compact automation cells, process equipment, and specialized laboratory systems.\u003c\/p\u003e\n\u003cp\u003eFor best performance, the module should be installed in a stable mechanical setup with proper vibration control, draft protection, static control, grounding, and suitable sample handling. For robotic or actuator-based loading, the system design should avoid shock loading, side loading, pan impact, over-travel, and contact with surrounding fixtures.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch3 style=\"margin-top: 0;\"\u003ePC, PLC, and Peripheral Integration\u003c\/h3\u003e\n\u003cp\u003eThe AD-4212D Series includes RS-232C communication and can connect to compatible PCs, PLCs, displays, printers, and peripheral devices using the appropriate cables and accessories.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003eOptional accessory options may include a tabletop breeze break, static eliminator, electrostatic field meter, compact printer, RS-232C\/Ethernet converter, remote controller, BCD controller, CC-Link controller, RS-232C cables, and RS-232C\/USB converter. Contact us before ordering if your project requires PLC communication, Ethernet conversion, BCD output, CC-Link, data logging, or custom automation integration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eCommon Questions About the AD-4212D Weighing Module\u003c\/h2\u003e\n\u003ch3\u003eWhat is the A\u0026amp;D AD-4212D used for?\u003c\/h3\u003e\n\u003cp\u003eThe AD-4212D is used to add microgram-level precision weighing into automated equipment, laboratory automation systems, pharmaceutical workflows, chemical processes, robotic weighing cells, micro-dosing systems, and advanced OEM machinery.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the AD-4212C and AD-4212D?\u003c\/h3\u003e\n\u003cp\u003eThe AD-4212C Series is a wide-range precision weighing module series with capacities up to 6200 g. The AD-4212D Series is focused on microgram and analytical precision weighing, with models offering readability down to 0.001 mg \/ 1 µg.\u003c\/p\u003e\n\u003ch3\u003eWhich AD-4212D model should I choose?\u003c\/h3\u003e\n\u003cp\u003eChoose the AD-4212D-33 if you need 1 µg readability across a 32 g capacity. Choose the AD-4212D-32 if you need Smart Range weighing with 1 µg readability in the lower range and 0.01 mg readability up to 32 g. Choose the AD-4212D-302 if you need 320 g capacity with 0.01 mg readability. Choose the AD-4212D-301 if you need 320 g capacity with 0.1 mg readability and faster stabilization.\u003c\/p\u003e\n\u003ch3\u003eDoes the AD-4212D include internal calibration?\u003c\/h3\u003e\n\u003cp\u003eThe AD-4212D Series includes an internal sensitivity adjustment weight for one-key accuracy checks and sensitivity adjustment.\u003c\/p\u003e\n\u003ch3\u003eCan the AD-4212D connect to a PC or PLC?\u003c\/h3\u003e\n\u003cp\u003eYes. The AD-4212D includes RS-232C communication and can connect to compatible PCs, PLCs, controllers, displays, printers, or data systems using the proper interface setup.\u003c\/p\u003e\n\u003ch3\u003eIs the AD-4212D waterproof?\u003c\/h3\u003e\n\u003cp\u003eThe AD-4212D has an IP65 rating when the water-resistant cap is placed on the pan support boss after the weighing pan and pan support are removed. Application suitability depends on the installation, cleaning method, cabling, environment, and surrounding equipment design.\u003c\/p\u003e\n\u003ch3\u003eIs the AD-4212D suitable for robotics?\u003c\/h3\u003e\n\u003cp\u003eYes, the AD-4212D can be used in robotic weighing and automated sample handling systems when the mechanical design protects the weighing module from impact, side loading, over-travel, vibration, drafts, and static.\u003c\/p\u003e\n\u003ch3\u003eDoes the AD-4212D support underhook weighing?\u003c\/h3\u003e\n\u003cp\u003eYes. The AD-4212D supports underhook weighing, which can be useful for suspended weighing, magnetic material weighing, and density measurement applications.\u003c\/p\u003e\n\u003ch3\u003eWhere can I buy the A\u0026amp;D AD-4212D in Canada?\u003c\/h3\u003e\n\u003cp\u003eA\u0026amp;D Weighing Wholesale Canada supplies AD-4212D microgram precision weighing modules in Canada through Cambridge Environmental Products, an authorized Canadian master distributor for A\u0026amp;D Weighing products.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 22px; margin-top: 32px; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eNeed Help Selecting an AD-4212D Module? \u003c\/h2\u003e\n\u003cp\u003eChoosing the right AD-4212D weighing module depends on your readability requirement, capacity, cycle time, tare load, sample handling method, environmental conditions, communication requirements, mounting design, and automation controls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact us before ordering if you are building the AD-4212D into pharmaceutical automation, laboratory automation, robotics, micro-dosing systems, formulation equipment, or OEM machinery.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003ca style=\"display: inline-block; padding: 12px 18px; background: #1f4e79; color: #ffffff; text-decoration: none; border-radius: 5px; font-weight: bold;\" href=\"\/fr\/pages\/contact\"\u003e Contact A\u0026amp;D Canada for Integration Support \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"A\u0026D Weighing","offers":[{"title":"AD-4212D-33","offer_id":55714297905225,"sku":"AD-4212D-33","price":0.0,"currency_code":"CAD","in_stock":false},{"title":"AD-4212D-32","offer_id":55714297937993,"sku":"AD-4212D-32","price":0.0,"currency_code":"CAD","in_stock":false},{"title":"AD-4212D-32S","offer_id":55714297970761,"sku":"AD-4212D-32S","price":9238.8,"currency_code":"CAD","in_stock":true},{"title":"AD-4212D-302","offer_id":55714298003529,"sku":"AD-4212D-302","price":0.0,"currency_code":"CAD","in_stock":false},{"title":"AD-4212D-301","offer_id":55714298036297,"sku":"AD-4212D-301","price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/3987\/6425\/files\/ad4212d-series.jpg?v=1782493164","url":"https:\/\/andweighing.ca\/fr\/products\/ad-4212d-weighing-module-canada","provider":"AND Wholesale Canada","version":"1.0","type":"link"}